4 Axes Motion Control Chip w. Interpolation Functionality: MCX314As/MCX314AL |
|
|
|
|
Page 3 of 3 Specifications - 4 Axes of control
- Data Bus 16/8 bits selectable
Interpolation Functions2-axes / 3-axes Linear Interpolation
- Interpolation Range Each axis: -2,147,483,646 ~ +2,147,483,646
- Interpolation Speed: 1 PPS ~ 4 MPPS
- Interpolation Accuracy: ±0.5 LSB (Within the range of whole interpolation)
Circular Interpolation
- Interpolation Range Each axis: -2,147,483,646 ~ +2,147,483,646
- Interpolation Speed: 1 PPS ~ 4 MPPS
- Interpolation Accuracy: ±1 LSB (Within the range of whole interpolation)
2 axes / 3 axes Bit Pattern Interpolation
- Interpolation Speed: 1 PPS ~ 4 MPPS (Dependent on CPU data writing time)
Related Functions of Interpolation- Can select any axis
- Constant vector speed
- Continuous interpolation
- Single step interpolation (Command/external signals)
Common Specifications of Each Axis- Drive Pulses Output (When CLK = 16 MHz)
- Pulse Output Speed Range: 1 PPS ~ 4 MPPS
- Pulse Output Accuracy within: ±0.1% (according to the setting speed)
- S-curve Jerk: 954 ~ 62.5 x 106 PPS/S² (Multiple = 1)
477 x 10³ ~ 31.25 x 109 PPS/S² (Multiple =500) - Accelerating / Decelerating Speed: 125 ~ 1 x 106 PPS/S (Multiple = 1)
62.5 × 10³ ~ 500 x 106 PPS/S (Multiple = 500) - Initial Speed: 1 ~ 8,000 PPS (Multiple = 1)
500 PPS ~ 4×106 PPS (Multiple = 500) - Drive Speed: 1 ~ 8,000 PPS (Multiple = 1)
500 PPS ~ 4×106 PPS (Multiple = 500) - Output-pulse Number: 0 ~ 4,294,967,295 / unlimited
- Speed Curve: Constant speed, symmetrical/non-symmetrical linear acceleration, symmetrical/non-symmetrical parabola S-curve acceleration/deceleration drive
- Index Pulse Drive Deceleration Mode auto (non-symmetrical linear acceleration is also allowed) / manual
- Output-pulse numbers and drive speeds changeable during the driving
- Triangle form prevention of linear acceleration fixed pulse drive and S-curve acceleration/deceleration fixed pulse drive
- Independent 2-pulse system or 1-pulse 1-direction system selectable
- Logical levels of drive pulse selectable, output pin switchable
Encoder Input
- A/B quadrature pulse style or Up/Down pulse style selectable
- Pulse of 1, 2 and 4 divisions selectable (A/B quadrature pulse style)
Position Counter
- Logic Position Counter (for output pulse t) range: -2,147,483,648 ~ +2,147,483,647
- Real Position Counter (for feedback pulse) range: -2,147,483,648 ~ +2,147,483,647
- Variable ring counter function, real position counter increase/decrease inversion function, and real position counter clear function by the IN2 signal Data read and write possible
Comparison Register
- COMP + Register Position comparison range: -2,147,483,648 ~ +2,147,483,647
- COMP - Register Position comparison range: -2,147,483,648 ~ +2,147,483,647
- Status and signal outputs for the comparisons of position counters
- Software limit functioned
Automatic home search
- Automatic execution of
- Step 1 (high-speed near home search)
- Step 2 (low-speed home search)
- Step 3 (low-speed encoder Z-phase search)
- Step 4 (high-speed offset drive). Enable/Disable of each step and search direction selectable
- Deviation counter clear output : Clear pulse width within the range of 10µ ~ 20msec and logical level selectable
Synchronous Action
- Activation factor
- Position counter >= COMP+ variation, position counter < COMP+ variation, position counter < COMP- variation, position counter >= COMP - variation, start of driving, termination of driving, IN3 signal-high, IN3 signal-low, LP read command, activation command.
- Action
- Start of ± fixed pulse drive, start of ± continuous pulse drive, drive decelerating stop, drive instant stop, saving position counter values, setting position counter values, settingan output pulse number, setting a drive speed, external signal output (DCC), and interrupt
Any action of other axes can be activated from the factor of the own axis. Interrupt (Interpolations Excluded)
- The factors of occurring interrupt:
- the drive-pulse outputting
- the start / finish of a constant-speed drive during the acceleration / deceleration driving
- the end of the driving
- the volume of position counter >= the volume of COMP-
- the volume of position counter < the volume of COMP-
- the volume of position counter >= the volume of COMP+
- the volume of position counter < the volume of COMP+
- terminating of automatic home search, synchronous action
Enable / disable for these factors selectable External Signal for Driving
- EXPP and EXPM signals for fixed pulse / continuous drive
- Driving in manual pulsar mode (encoder input)
External Deceleration / Sudden Stop Signal - IN0 ~ 3: 4 points for each axis
Enable / disable and logical levels selectable Servo Motor Input Signal
- ALARM (Alarm), INPOS (In Position Check), DCC (Pin shared between deviation counter clear output and DRIVE)
Enable / disable and logical levels selectable General Output Signal
- OUT0 ~ 7: 8 points for each axis (wherein 4 points use with drive status output signal pin)
Driving Status Signal Output - ASND (speed accelerating), DSND (speed decelerating), CMPP (position >= COMP+), CMPM (position < COMP-)
Drive status and status registers readable Limit Signals Input
- 2 points, for each + and - side
Logical levels and decelerating / sudden stop selectable Emergency Stop Signal Input
Contents of integral type filters
- Equipped with integral filters in the input column of each input signal. One time constant can be selected from eight types.
Electrical Characters- Temperature Range for Driving (MCX314As): 0° ~ +85°C (32°F ~ 185°F)
- Temperature Range for Driving (MCX314AL): -40°° ~ +85°C (-40°F ~ 185°F)
- Power Voltage for Driving (MCX314As): +5V ± 5 %
- Power Voltage for Driving (MCX314AL): +3.3V ± 5 %
- Consumption current (MCX314As): 70mA typ (112mA max)
- Consumption current (MCX314AL): 21mA typ (30mA max)
- Input Signal Level (MCX314As): CMOS, TTL connectable
- Input Signal Level (MCX314AL): CMOS, TTL connectable (5V tolerant)
- Output Signal Level (MCX314As): 5V CMOS Level
- Output Signal Level (MCX314AL): 3.3V CMOS Level (only TTL can be connnected for 5V type)
- Input Clock Pulse (MCX314As): 16 MHz (Standard)
- Input Clock Pulse (MCX314AL): 16 MHz (Standard); 32 MHz (max.)
Package- 144-pin plastic LQFP, pitch = 0.5mm lead free item
- Dimension : 20 × 20 × 1.4 mm (External size including pins : 22 × 22 × 1.6 mm)
|
|
Newsflash
|
Motion Control Cards with Special PIEZO (Ceramic) Motor Functions Motion Control Chips with special functions to compensate PIEZO Motor behaviour Products Names: - POSYS® 1800-PIEZO Series
- POSYS® 1900-PIEZO Series
Description: The POSYS® 1800-PIEZO and POSYS® 1900-PIEZO are motion control cards (PC-104, PCI-bus) for servo and stepper motors and provide one to four axes of motion. The functionality of these series has been significantly improved by using a special motion control chip with enhanced PIEZO (Ceramic) control functions. It is now possible to compensate the special behaviour of PIEZO (Ceramic) motors like for example stiction. |
|
Read more...
|
|
|
| |
|
|