Startseite arrow Produkte arrow Motion Control Chipsätze arrow 4-Achsen Motion Controller mit Interpolationsfunktionalität

User Login

4-Achsen Motion Controller mit Interpolationsfunktionalität PDF Drucken E-Mail
Beitragsinhalt
4-Achsen Motion Controller mit Interpolationsfunktionalität
Merkmale
Spezifikationen

Spezifikationen

  • 4 Axes of control
  • Data Bus 16/8 bits selectable

Interpolation Functions

2-axes / 3-axes Linear Interpolation

  • Interpolation Range Each axis: -2,147,483,646 ~ +2,147,483,646
  • Interpolation Speed: 1 PPS ~ 4 MPPS
  • Interpolation Accuracy: ±0.5 LSB (Within the range of whole interpolation)

Circular Interpolation

  • Interpolation Range Each axis: -2,147,483,646 ~ +2,147,483,646
  • Interpolation Speed: 1 PPS ~ 4 MPPS
  • Interpolation Accuracy: ±1 LSB (Within the range of whole interpolation)

2 axes / 3 axes Bit Pattern Interpolation

  • Interpolation Speed: 1 PPS ~ 4 MPPS (Dependent on CPU data writing time)

Related Functions of Interpolation

  • Can select any axis
  • Constant vector speed
  • Continuous interpolation
  • Single step interpolation (Command/external signals)

Common Specifications of Each Axis

  • Drive Pulses Output (When CLK = 16 MHz)
  • Pulse Output Speed Range: 1 PPS ~ 4 MPPS
  • Pulse Output Accuracy within: ±0.1% (according to the setting speed)
  • S-curve Jerk: 954 ~ 62.5 x 106 PPS/S² (Multiple = 1)
                        477 x 10³ ~ 31.25 x 109 PPS/S² (Multiple =500)
  • Accelerating / Decelerating Speed: 125 ~ 1 x 106 PPS/S (Multiple = 1)
                                                       62.5 × 10³ ~ 500 x 106 PPS/S (Multiple = 500)
  • Initial Speed: 1 ~ 8,000 PPS (Multiple = 1)
                         500 PPS ~ 4×106 PPS (Multiple = 500)
  • Drive Speed: 1 ~ 8,000 PPS (Multiple = 1)
                        500 PPS ~ 4×106 PPS (Multiple = 500)
  • Output-pulse Number: 0 ~ 4,294,967,295 / unlimited
  • Speed Curve: Constant speed, symmetrical/non-symmetrical linear acceleration, symmetrical/non-symmetrical parabola S-curve acceleration/deceleration drive
  • Index Pulse Drive Deceleration Mode auto (non-symmetrical linear acceleration is also allowed) / manual
  • Output-pulse numbers and drive speeds changeable during the driving
  • Triangle form prevention of linear acceleration fixed pulse drive and S-curve acceleration/deceleration fixed pulse drive
  • Independent 2-pulse system or 1-pulse 1-direction system selectable
  • Logical levels of drive pulse selectable, output pin switchable

Encoder Input

  • A/B quadrature pulse style or Up/Down pulse style selectable
  • Pulse of 1, 2 and 4 divisions selectable (A/B quadrature pulse style)

Position Counter

  • Logic Position Counter (for output pulse t) range: -2,147,483,648 ~ +2,147,483,647
  • Real Position Counter (for feedback pulse) range: -2,147,483,648 ~ +2,147,483,647
  • Variable ring counter function, real position counter increase/decrease inversion function, and real position counter clear function by the IN2 signal Data read and write possible

Comparison Register

  • COMP + Register Position comparison range: -2,147,483,648 ~ +2,147,483,647
  • COMP - Register Position comparison range: -2,147,483,648 ~ +2,147,483,647
  • Status and signal outputs for the comparisons of position counters
  • Software limit functioned

Automatic home search

  • Automatic execution of
    • Step 1 (high-speed near home search)
    • Step 2 (low-speed home search)
    • Step 3 (low-speed encoder Z-phase search)
    • Step 4 (high-speed offset drive). Enable/Disable of each step and search direction selectable
  • Deviation counter clear output : Clear pulse width within the range of 10µ ~ 20msec and logical level selectable

Synchronous Action

  • Activation factor
    • Position counter >= COMP+ variation, position counter < COMP+ variation, position counter < COMP- variation, position counter >= COMP - variation, start of driving, termination of driving, IN3 signal-high, IN3 signal-low, LP read command, activation command.
  • Action
    • Start of ± fixed pulse drive, start of ± continuous pulse drive, drive decelerating stop, drive instant stop, saving position counter values, setting position counter values, settingan output pulse number, setting a drive speed, external signal output (DCC), and interrupt
Any action of other axes can be activated from the factor of the own axis.

Interrupt (Interpolations Excluded)

  • The factors of occurring interrupt:
    • the drive-pulse outputting
    • the start / finish of a constant-speed drive during the acceleration / deceleration driving
    • the end of the driving
    • the volume of position counter >= the volume of COMP-
    • the volume of position counter < the volume of COMP-
    • the volume of position counter >= the volume of COMP+
    • the volume of position counter < the volume of COMP+
    • terminating of automatic home search, synchronous action
Enable / disable for these factors selectable

External Signal for Driving

  • EXPP and EXPM signals for fixed pulse / continuous drive
  • Driving in manual pulsar mode (encoder input)
External Deceleration / Sudden Stop Signal
 
  • IN0 ~ 3: 4 points for each axis

Enable / disable and logical levels selectable

Servo Motor Input Signal

  • ALARM (Alarm), INPOS (In Position Check), DCC (Pin shared between deviation counter clear output and DRIVE)
Enable / disable and logical levels selectable

General Output Signal

  • OUT0 ~ 7: 8 points for each axis (wherein 4 points use with drive status output signal pin)
Driving Status Signal Output
  • ASND (speed accelerating), DSND (speed decelerating), CMPP (position >= COMP+), CMPM (position < COMP-) 
Drive status and status registers readable

Limit Signals Input

  • 2 points, for each + and - side 
Logical levels and decelerating / sudden stop selectable

Emergency Stop Signal Input

  • EMG, 1 point for 4 axes

Contents of integral type filters

  • Equipped with integral filters in the input column of each input signal. One time constant can be selected from eight types.

Electrical Characters

  • Temperature Range for Driving (MCX314As): 0° ~ +85°C (32°F ~ 185°F)
  • Temperature Range for Driving (MCX314AL): -40°° ~ +85°C (-40°F ~ 185°F)
  • Power Voltage for Driving (MCX314As): +5V ± 5 %
  • Power Voltage for Driving (MCX314AL): +3.3V ± 5 %
  • Consumption current (MCX314As): 70mA typ (112mA max)
  • Consumption current (MCX314AL): 21mA typ (30mA max)
  • Input Signal Level (MCX314As): CMOS, TTL connectable
  • Input Signal Level (MCX314AL): CMOS, TTL connectable (5V tolerant)
  • Output Signal Level (MCX314As): 5V CMOS Level
  • Output Signal Level (MCX314AL): 3.3V CMOS Level (only TTL can be connnected for 5V type)
  • Input Clock Pulse (MCX314As): 16 MHz (Standard)
  • Input Clock Pulse (MCX314AL): 16 MHz (Standard); 32 MHz (max.)

Package

  • 144-pin plastic LQFP, pitch = 0.5mm lead free item
  • Dimension : 20 × 20 × 1.4 mm (External size including pins : 22 × 22 × 1.6 mm)


 
< zurück

Newsflash

Motion Control Cards with Special PIEZO (Ceramic) Motor Functions

Motion Control Chips with special functions to compensate PIEZO Motor behaviour

Products Names:

  • POSYS® 1800-PIEZO Series 
  • POSYS® 1900-PIEZO Series

Description:

The POSYS® 1800-PIEZO and POSYS® 1900-PIEZO are motion control cards (PC-104, PCI-bus) for servo and stepper motors and provide one to four axes of motion. The functionality of these series has been significantly improved by using a special motion control chip with enhanced PIEZO (Ceramic) control functions. It is now possible to compensate the special behaviour of PIEZO (Ceramic) motors like for example stiction.

weiter …
 